OEM 3000 Watt Off Grid Pure Sine Wave Inverter with bypass function
Description:
pure sine wave inverter specifications:
MODEL
|
TFS3000-112
|
TFS3000-124
|
TFS3000-148
|
TFS3000-212
|
TFS3000-224
|
TFS3000-248
|
|
Output
|
AC Voltage
|
100/110/120VAC
|
220/230/240VAC
|
||||
Rated Power
|
3000W
|
||||||
Surge Power
|
Load 120~150%(3min.);3000W(3sec; resistive)
|
||||||
Waveform
|
Pure Sine Wave(THD<3%)
|
||||||
Frequency
|
50/60Hz ±0.05%
|
||||||
AC Regulation
|
±5%
|
±10%
|
|||||
Power Factor Allowed
|
COSθ-90°~COSθ+90°
|
||||||
Standard Receptacles
|
USA/British/Franch/Schuko /UK/Australia/Universal etc. optional
|
||||||
LED Indicator
|
Green for power on, red for faulty status
|
||||||
USB port
|
5V 2.1A
|
5V 2.1A
|
------
|
5V 2.1A
|
5V 2.1A
|
------
|
|
LCD display
|
voltage, power, protection status ( optional)
|
||||||
Remote control function
|
default
|
||||||
Remote controller
|
CR80/CRD80/CRD99 optional
|
||||||
Input
|
No Load Current Draw
|
≤1.1A
|
≤0.80A
|
≤0.70A
|
≤1.1A
|
≤0.80A
|
≤0.70A
|
DC Voltage
|
12VDC
|
24VDC
|
48VDC
|
12VDC
|
24VDC
|
48VDC
|
|
Voltage Range
|
10.5~15VDC
|
21~30VDC
|
42~60VDC
|
10.5~15VDC
|
21~30VDC
|
42~60VDC
|
|
Efficiency(Typ.)
|
89%~93%
|
||||||
Fuse
|
40A×6
|
20A×6
|
10A×6
|
40A×6
|
20A×6
|
10A×6
|
|
Remote Control
|
Function (optional)
|
||||||
Protection
|
BAT. Low Alarm
|
10.5±0.5VDC
|
21±1.0VDC
|
42±2.0VDC
|
10.5±0.5VDC
|
21±1.0VDC
|
42±2.0VDC
|
BAT. Low Shutdown
|
10±0.5VDC
|
20±1.0VDC
|
40±2.0VDC
|
10±0.5VDC
|
20±1.0VDC
|
40±2.0VDC
|
|
Over Load
|
Shut down output voltage , restart to recover
|
||||||
Over Voltage
|
15.5±0.5VDC
|
31±1.0VDC
|
62±2.0VDC
|
15.5±0.5VDC
|
31±1.0VDC
|
62±2.0VDC
|
|
Over Temperature
|
Shut down output voltage , recover automatically after temperature goes down
|
||||||
Output Short
|
Shut down output voltage , restart to recover
|
||||||
DC Input Reverse Polarity
|
By fuse
|
||||||
Earth Fault
|
Shut off o/p when the load has electrical leakage
|
||||||
Soft Start
|
Yes, 3-5 Seconds
|
||||||
Environment
|
Working Temp.
|
0~+50℃
|
|||||
Working Humidity
|
20~90%RH non-condensing
|
||||||
Storage Temp.&Humidity
|
-30~+70℃,10~95%RH
|
||||||
Safety & EMC
|
Safety Standards
|
Certified UL 458(only for "GFCI" receptacles)
|
Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013.
|
||||
Isolation Resistance
|
I/P-O/P:100M Ohms/500VDC
|
||||||
EMI Conduction &
Radiation |
Certified FCC class A
|
Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3;
|
|||||
EMS Immunity
|
------
|
Certified IEC61000-4-3, IEC61000-4-6
|
|||||
E-MARK
|
------
|
Certified ECE RIO.05:2014
|
Product picures: